Atomizery klasyczne płaski strumień 1/4"

mw

 

Atomizery klasyczne płaski strumień 1/4"

Przepływ

l/h & / NI/min
Liquid flow rate (l/h): min = 0,50  max = 280
Air flow rate (Nl/min): min = 20,0  max = 685

gph & scfm
Liquid flow rate (gph): min = 0,13  max = 73,9
Air flow rate (scfm): min = 0,71  max = 24,2

Materiały

AISI 303 s.s., 316L s.s.
LUCITE®, PVC
Nickel Plated)

 

SET-UPS: Pressure principle – Internal mix – Flat spray – 1/4″

Atomizery klasyczne płaski strumień 1/4"

Płaski strumień
These single orifice set-ups produce a flat fan shaped atomized sprays.More precise details on the spray dimensions are given in the table on the right side of the page.The spray length can reach from 1.800 to 5.200 mm depending upon the set-up type and operating conditions.See advice on adjustment for flow rates and droplet size given at page 8.

---

Abbreviations ATOMIZERS

To obtain the complete code for an atomizer, it is necessary to use the set-up code you have chosen from the performance table and complete it with the code for body and options as follows. • Replace the first two letters in the set-up code (SU) with the code for the standard body (MW). • Add the code for the material you require. • Add the code for the required options, if any, and the code for thread type.

atomizzatore    

AISI 303 s.s., 316L s.s.
LUCITE®, PVC
Nickel Plated)

ATO bar p14 1 4 Flat Internal Pressure rev1

ATO psi p14 1 4 Flat Internal Pressure

 

SET-UPS: Siphon principle – Internal mix – Flat spray – 1/4″

Atomizery klasyczne płaski strumień 1/4"

Płaski strumień
These set-ups are designed to work with a liquid fed out of an ambient pressure container, either by liquid siphoning or by gravity head.Therefore the performance tables give the water flow rate for both suction head (blue background) and gravity head (white background).The approximate spray depending upon set-up type and operating conditions are given from the table on the right.

---

Abbreviations ATOMIZERS

To obtain the complete code for an atomizer, it is necessary to use the set-up code you have chosen from the performance table and complete it with the code for body and options as follows. • Replace the first two letters in the set-up code (SU) with the code for the standard body (MW). • Add the code for the material you require. • Add the code for the required options, if any, and the code for thread type.

atomizzatore    

AISI 303 s.s., 316L s.s.
LUCITE®, PVC
Nickel Plated)

ATO bar p15.2 1 4 Flat Internal Siphon

ATO psi p15.2 1 4 Flat Internal Siphon

 

SET-UPS: Pressure principle – External mix – Flat Fan spray – 1/4″

Atomizery klasyczne płaski strumień 1/4"

Płaski strumień
These set-ups are designed to have two different paths for air and liquid and to eject them through different orifices so that the atomized spray is produced from their impact in the immediate surroundings of the orifices. It is possible therefore to atomize viscous liquids as well as any liquid which might originate a solid build up in the mixing chamber of an ordinary internal mix atomizer.Also, liquid and air pressure can be adjusted independently from each other, which allows for an easy, steady state atomizer regulation.The approximate spray depending upon set-up type and operating conditions are given from the table on the right.

---

Abbreviations ATOMIZERS

To obtain the complete code for an atomizer, it is necessary to use the set-up code you have chosen from the performance table and complete it with the code for body and options as follows. • Replace the first two letters in the set-up code (SU) with the code for the standard body (MW). • Add the code for the material you require. • Add the code for the required options, if any, and the code for thread type.

AT PAG16    

AISI 303 s.s., 316L s.s.
LUCITE®, PVC
Nickel Plated)

ATO bar p16 1 4 Flat External Pressure

ATO bar p17 1 4 Flat External Pressure

ATO psi p16 1 4 Flat External Pressure

ATO psi p17 1 4 Flat External Pressure